Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Arq. gastroenterol ; 51(2): 133-138, Apr-Jun/2014. tab, graf
Article in English | LILACS | ID: lil-713581

ABSTRACT

Context One of the limitations of 13C-urea breath test for Helicobacter pylori infection diagnosis in Brazil is the substrate acquisition in capsule presentation. Objectives The purpose of this study was to evaluate a capsule-based 13C-urea, manipulated by the Pharmacy Division, for the clinical practice. Methods Fifty patients underwent the conventional and the capsule breath test. Samples were collected at the baseline and after 10, 20 and 30 minutes of 13C-urea ingestion. Urease and histology were used as gold standard in 83 patients. Results In a total of 50 patients, 17 were positive with the conventional 13C-urea (75 mg) breath test at 10, 20 and 30 minutes. When these patients repeated breath test with capsule (50 mg), 17 were positive at 20 minutes and 15 at 10 and 30 minutes. The relative sensitivity of 13C-urea with capsule was 100% at 20 minutes and 88.24% at 10 and at 30 minutes. The relative specificity was 100% at all time intervals. Among 83 patients that underwent capsule breath test and endoscopy the capsule breath test presented 100% of sensitivity and specificity. Conclusions Capsule based breath test with 50 mg 13C-urea at twenty minutes was found highly sensitive and specific for the clinical setting. HEADINGS- Helicobacter pylori. Breath Test. Urea, analysis. .


Contexto Uma das limitações para o teste respiratório com 13C-uréia ser incorporado na prática clínica no Brasil para diagnóstico de infecção pelo Helicobacter pylori (H. pylori) é a aquisição do substrato em apresentação de cápsula. Objetivos O objetivo deste estudo foi avaliar a utilidade de 13C-uréia em cápsula, manipulada pela Divisão de Farmácia de um Hospital terciário para a prática clínica. Métodos Cinquenta pacientes foram submetidos ao teste respiratório convencional com 75mg de 13C-uréia e ao teste com cápsula de 50 mg de 13C-uréia. Amostras de ar expirado foram coletadas no basal e após 10, 20 e 30 minutos da ingestão de 13C-uréia para definição do melhor tempo de coleta. A urease e a histologia foram usadas como padrão ouro em 83 pacientes que se submeteram ao teste respiratório com único ponto de coleta. Resultados Num total de 50 pacientes, 17 foram positivos com teste respiratório convencional com 75 mg de 13C-uréia aos 10, 20 e 30 minutos. Quando esses pacientes repetiram o teste respiratório com 13C-uréia em cápsulas de 50 mg, 17 foram positivos aos 20 minutos (Índice Kappa 1,0; P<0,05) e 15 aos 10 e 30 minutos (Índice Kappa 0,90; P<0,05). A sensibilidade relativa da 13C-uréia em cápsulas de 50 mg foi 100% aos 20 minutos e 88,24% aos 10 e 30 minutos. A especificidade relativa foi de 100% em todos os intervalos de tempo. Entre 83 pacientes que se submeteram ao teste respiratório com cápsula e endoscopia, aqueles que eram H. pylori positivos tiveram teste respiratório positivo e aqueles H. pylori negativo tiveram teste respiratório negativo, mostrando sensibilidade e especificidade de 100%. Conclusões O teste respiratório com cápsula de 50 mg de 13C-uréia ...


Subject(s)
Female , Humans , Male , Middle Aged , Breath Tests/methods , Helicobacter pylori , Helicobacter Infections/diagnosis , Stomach Diseases/microbiology , Urea , Urease , Capsules , Endoscopy, Gastrointestinal , Sensitivity and Specificity , Stomach Diseases/diagnosis
3.
In. Cipriano, Sonia Lucena; Pinto, Vanusa Barbosa; Chaves, Cleuber Esteves. Gestão estratégica em farmácia hospitalar: aplicação pratica de um modelo de gestão para qualidade. São Paulo, Atheneu, 2009. p.23-41.
Monography in Portuguese | LILACS | ID: lil-544906
4.
In. Cipriano, Sonia Lucena; Pinto, Vanusa Barbosa; Chaves, Cleuber Esteves. Gestão estratégica em farmácia hospitalar: aplicação pratica de um modelo de gestão para qualidade. São Paulo, Atheneu, 2009. p.43-56.
Monography in Portuguese | LILACS | ID: lil-544907
5.
In. Cipriano, Sonia Lucena; Pinto, Vanusa Barbosa; Chaves, Cleuber Esteves. Gestão estratégica em farmácia hospitalar: aplicação pratica de um modelo de gestão para qualidade. São Paulo, Atheneu, 2009. p.63-67.
Monography in Portuguese | LILACS | ID: lil-544908
6.
In. Cipriano, Sonia Lucena; Pinto, Vanusa Barbosa; Chaves, Cleuber Esteves. Gestão estratégica em farmácia hospitalar: aplicação pratica de um modelo de gestão para qualidade. São Paulo, Atheneu, 2009. p.69-77.
Monography in Portuguese | LILACS | ID: lil-544909
7.
In. Cipriano, Sonia Lucena; Pinto, Vanusa Barbosa; Chaves, Cleuber Esteves. Gestão estratégica em farmácia hospitalar: aplicação pratica de um modelo de gestão para qualidade. São Paulo, Atheneu, 2009. p.79-99.
Monography in Portuguese | LILACS | ID: lil-544910
SELECTION OF CITATIONS
SEARCH DETAIL